Technical data 1.Externality size: 445mm*200mm*145mm 2.Max. self consumption: ≤3W 3.Accuracy of temperature measuring: ±2℃ 4.Range of temperature measuring: 0~99℃ 5.Power of controlled pumps (temperature difference circulation pump, water-using end circulation pump): <600W 6.Electronic booster power: ≤2000W 7.System working pressure: 0.6MPA 8.Input signal: 3 temperature sensors (for top of tank, for heat collector, for bottom of tank) 9.Output signal: 3 (electronic booster, temperature difference circulation pump and water-using end circulation pimp) Main functions - Display clock and week
- Display temperature
- Temperature difference circulation pumps provide three working scopes for choose
- Three periods timing heating
- Heat collector frost protection
- Memory function
- Water tank temperature setting
Display the system pressure |